Requirements guide

Alberta Egress Window Requirements

Alberta guidance identifies a minimum unobstructed opening area of 0.35 m², with no opening dimension less than 380 mm. Confirm the current requirements for your exact project before construction.

Get an egress quote

At a glance

  • Most unsprinklered bedrooms without an exterior door need at least one window that can be opened from inside without tools or special knowledge.
  • The clear opening must be at least 0.35 m², and no clear-opening dimension can be less than 380 mm.
  • When the window opens into a well, Alberta guidance calls for at least 760 mm of clear space in front of the escape window.

Related Edmonton guides

Unobstructed opening matters

Measure the clear space a person can actually pass through with the window fully open—not the frame, glass or rough-opening dimensions.

Window wells also affect escape

A compliant window can still be difficult to use if the well is too tight, obstructed or cannot remain open without special tools. Review the full escape path.

The three measurements that matter

The Alberta requirement is based on the unobstructed opening available when the operable portion is fully open. It is not the glass size, frame size or concrete opening. Hardware, screens that are not readily removable, sash overlap and opening limiters can reduce the usable area.

A clear width and height can each exceed 380 mm while the total area still falls below 0.35 m². Both tests must pass. Multiply the clear width by the clear height using the same units; 0.35 m² equals about 3.77 ft² or 543 in².

  • Minimum unobstructed area: 0.35 m².
  • Minimum clear width or height: 380 mm in either direction.
  • The window must open from inside without keys, tools or special knowledge.
  • The required opening must be achieved without removing a sash or fixed security bar.
  • The window cannot need a prop or support to remain open.

Why window style changes the answer

A casement window swings most of its sash out of the opening and can often achieve a larger clear area within a compact frame. A horizontal slider generally exposes only part of its total frame width. Hopper and awning windows can be constrained by hinges and operating hardware.

Do not approve a product from brochure dimensions alone. Ask the supplier for the exact net-clear-opening width, height and area for the model and size being ordered, including the effect of any removable screen or safety hardware.

  • Casement: efficient clear opening, but confirm swing clearance in the well.
  • Slider: familiar and simple, but may need a wider overall unit.
  • Inward-opening style: preserve exterior clearance but needs interior space.
  • Outward-opening awning: the required well clearance is measured beyond the outer edge of the open sash.

Window-well clearance and sill access

Alberta’s bedroom-window bulletin states that a well in front of a designated escape window needs at least 760 mm of clearance. For an outward-opening awning window, that clear distance must remain beyond the open sash. Covers, ladders, planters and stored items should not block the path.

The code bulletin does not set a maximum bedroom-window sill height, but recommends keeping an emergency-exit sill no higher than 1.5 m above the floor. Where a basement sill is higher, fixed built-in access may make the route more usable. Confirm any proposed step or built-in with the permit reviewer.

A practical measuring method

Open the window fully and measure the narrowest unobstructed width and height through which a person would pass. Do not measure to movable hardware that remains in the path. Multiply the two measurements to calculate area, then test each dimension separately against 380 mm.

  • Measure in millimetres for fewer conversion errors.
  • Area in m² = width in metres × height in metres.
  • Photograph the opening with the tape measure visible.
  • Verify manufacturer net-clear-opening data before ordering a new window.
  • Treat the website calculator as a preliminary screen, not permit approval.

Requirements can depend on the building, room use and adopted code. Confirm the current interpretation with the City of Edmonton before construction.

Useful next steps for this project

Frequently asked questions

Does a 15-inch by 15-inch opening comply?

No. Although both dimensions are about 380 mm, the area is only about 0.144 m²—far below the required 0.35 m².

Does every basement window have to be egress-sized?

No. The bedroom rule applies to sleeping rooms unless another permitted exception applies, such as an exterior door or an applicable sprinkler provision. Other project and natural-light requirements may still affect non-bedroom windows.

Can security bars stay on an egress window?

Only if the required opening remains usable from inside without tools or special knowledge. Fixed bars that obstruct the opening are not acceptable for the required escape window.

Sources and further reading

Reviewed September 2026. Building requirements, permit processes and costs can change; confirm current details for your property before construction.